극저온 및 특수 VALVE
극저온 및 특수 VALVE 정보를 안내드립니다.
Design pressure : 5.0Mpa
Design temperature : -196℃~75℃
Kind of fluid : LN₂, LO₂, LAr, LCO₂, LNG, LC₂H₄
Hydrostatic test pressure : 7.5 Mpa
Pneumatic test pressure : 5.5 Mpa
“SS Cryogenic Long-stem Globe Valve” is designed to provide exactly shut-off of cryogenic liquid systems.
This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂, LO₂, LAr and LNG. Unique design and manufacturing technology give much better price and more reliability.
Specifications | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Model No. | SIZE | ØD | d | d1 | L | L1 | I | W | H | Cv |
NS100s-10A-SW | 3/8”(10A) | 12 | 17.5 | 26 | 56 | 8 | 8 | 80 | 200 | 2.0 |
NS100s-15A-SW | 1/2″(15A) | 15 | 21.9 | 30 | 62 | 9 | 10 | 80 | 245 | 2.9 |
NS100s-20A-SW | 3/4″(20A) | 20 | 27.4 | 36.8 | 70 | 11 | 12 | 100 | 270 | 6.1 |
NS100s-25A-SW | 1″(25A) | 25 | 34.2 | 44 | 76 | 12 | 13.5 | 100 | 285 | 9.3 |
NS100s-32A-SW | 1-1/4”(32A) | 32 | 42.9 | 52 | 90 | 13 | 16 | 100 | 350 | 14 |
NS100s-40A-SW | 11/2″(40A) | 40 | 48.8 | 62 | 110 | 14 | 22 | 140 | 430 | 25 |
NS100s-50A-SW | 2″(50A) | 50 | 61 | 74 | 130 | 15 | 25 | 140 | 460 | 38 |
NS100s-80A-SW | 3″(80A) | 80 | 78 | 100 | 210 | - | 32 | 200 | 600 | 56 |
NS100s-100A-SW | 4″(100A) | 100 | 98 | 130 | 280 | - | 38 | 250 | 700 | 140 |
Design pressure : 5.0Mpa
Design temperature : -40℃~75℃
Kind of fluid : LN₂, LO₂, LAr, LCO₂, LNG, LC₂H₄
Hydrostatic test pressure : 7.5 Mpa
Pneumatic test pressure : 5.5 Mpa
“SS Cryogenic Short-stem Globe Valve” is designed to provide positive shut-off of cryogenic gas systems. This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for O₂, N₂, Ar and NG.
Specifications | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Model No. | SIZE | ØD | d | d1 | L | L1 | I | W | H | Cv |
NS110s-10A-SW | 3/8”(10A) | 12 | 17.5 | 26 | 56 | 8 | 8 | 80 | 160 | 2.0 |
NS110s-15A-SW | 1/2″(15A) | 15 | 21.9 | 30 | 62 | 9 | 10 | 80 | 165 | 2.9 |
NS110s-20A-SW | 3/4″(20A) | 20 | 27.4 | 36.8 | 70 | 11 | 12 | 100 | 180 | 6.1 |
NS110s-25A-SW | 1″(25A) | 25 | 34.2 | 44 | 76 | 12 | 13.5 | 100 | 190 | 9.3 |
NS110s-32A-SW | 1-1/4”(32A) | 32 | 42.9 | 52 | 90 | 13 | 16 | 100 | 230 | 14 |
NS110s-40A-SW | 11/2″(40A) | 40 | 48.8 | 62 | 110 | 14 | 22 | 140 | 270 | 25 |
NS110s-50A-SW | 2″(50A) | 50 | 61 | 74 | 130 | 15 | 25 | 140 | 290 | 38 |
NS110s-80A-SW | 3″(80A) | 80 | 78 | 100 | 210 | - | 32 | 200 | 350 | 56 |
NS110s-100A-SW | 4″(100A) | 100 | 98 | 130 | 280 | - | 38 | 250 | 420 | 140 |
Design pressure : 5.0Mpa
Design temperature : -196℃~75℃
Kind of fluid : LN₂, LO₂, LAr, LCO₂, LNG, LC₂H₄
Hydrostatic test pressure : 7.5 Mpa
Pneumatic test pressure : 5.5 Mpa
“SS Cryogenic Lift Check Valve” is designed for use as a check valve which allows fluids to flow in one direction in cryogenic liquid systems.
This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂, LAr, and LNG.
Specifications | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Model No. | SIZE | ØD | d | d1 | L | L1 | I | H | Cv | |
NS200s-15A | 1/2″(15A) | 15 | 21.9 | 30 | 62 | 9 | 10 | 53 | 2.9 | |
NS200s-20A | 3/4″(20A) | 20 | 27.4 | 36.8 | 70 | 11 | 12 | 62 | 6.1 | |
NS200s-25A | 1″(25A) | 25 | 34.2 | 44 | 76 | 12 | 13.5 | 67 | 9.3 | |
NS200s-40A | 11/2″(40A) | 40 | 48.8 | 62 | 110 | 14 | 22 | 267 | 22 | |
NS200s-50A | 2″(50A) | 50 | 61 | 74 | 130 | 15 | 25 | 275 | 38 |
Design pressure : 3.0Mpa
Design temperature : -196℃~75℃
Kind of fluid : LN2, LO2, LAr, LCO2, LNG, LC₂H₄
Hydrostatic test pressure : 4.5 Mpa
Pneumatic test pressure : 3.3 Mpa
“BC Cryogenic Long-stem Globe Valve” is designed to provide positive shut-off of cryogenic liquid systems.
This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂ and LAr. Unique design and manufacturing technology give much better price and more reliability.
Specifications | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Model No. | SIZE | ØD | d | d1 | L | L1 | I | W | H | Cv |
NS100b-10A-SW | 3/8”(10A) | 12 | 17.5 | 26 | 56 | 8 | 8 | 80 | 160 | 2 |
NS100b-15A-SW | 1/2″(15A) | 15 | 21.9 | 30 | 62 | 9 | 10 | 80 | 165 | 2.9 |
NS100b-20A-SW | 3/4″(20A) | 20 | 27.4 | 36.8 | 70 | 11 | 12 | 100 | 285 | 6.1 |
NS100b-25A-SW | 1″(25A) | 25 | 34.2 | 44 | 76 | 12 | 13.5 | 100 | 285 | 9.3 |
NS100b-32A-SW | 1-1/4”(32A) | 32 | 42.9 | 52 | 90 | 13 | 16 | 100 | 350 | 14 |
NS100b-40A-SW | 11/2″(40A) | 40 | 48.8 | 62 | 110 | 14 | 22 | 140 | 430 | 25 |
NS100b-50A-SW | 2″(50A) | 50 | 61 | 74 | 130 | 15 | 25 | 140 | 460 | 38 |
Design pressure : 3.0Mpa
Design temperature : -196℃~75℃
Kind of fluid : N₂, O₂, Ar, CO₂, NG, C₂H₄
Hydrostatic test pressure : 4.5 Mpa
Pneumatic test pressure : 3.3 Mpa
“BC Cryogenic Short-stem Globe Valve” is designed to provide positive shut-off of cryogenic gas systems.
This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂, LAr and LNG.”
Specifications | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Model No. | SIZE | ØD | d | d1 | L | L1 | I | W | H | Cv |
NS110B-10A-SW | 3/8”(10A) | 12 | 17.5 | 26 | 56 | 8 | 8 | 80 | 160 | 2 |
NS110B-15A-SW | 1/2″(15A) | 15 | 21.9 | 30 | 62 | 9 | 10 | 80 | 165 | 2.9 |
NS110B-20A-SW | 3/4″(20A) | 20 | 27.4 | 36.8 | 70 | 11 | 12 | 100 | 180 | 6.1 |
NS110B-25A-SW | 1″(25A) | 25 | 34.2 | 44 | 76 | 12 | 13.5 | 100 | 190 | 9.3 |
NS110B-32A-SW | 1-1/4”(32A) | 32 | 42.9 | 52 | 90 | 13 | 16 | 100 | 230 | 14 |
NS110B-40A-SW | 11/2″(40A) | 40 | 48.8 | 62 | 110 | 14 | 22 | 140 | 270 | 25 |
NS110B-50A-SW | 2″(50A) | 50 | 61 | 74 | 130 | 15 | 25 | 140 | 290 | 38 |
Design pressure : 3.0Mpa
Design temperature : -196℃~75℃
Kind of fluid : LN₂, LO₂, LAr, LCO₂, LNG, LC₂H₄
Hydrostatic test pressure : 4.5 Mpa
Pneumatic test pressure : 3.3 Mpa
“BC Cryogenic Lift Check Valve” is designed to provide positive shutoff of cryogenic gas systems.
This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂, LAr and LNG.”
Specifications | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Model No. | SIZE | ØD | d | d1 | L | L1 | I | H | Cv | |
NS200b-15A | 1/2″(15A) | 15 | 21.9 | 30 | 62 | 9 | 10 | 53 | 2.9 | |
NS200b-20A | 3/4″(20A) | 20 | 27.4 | 36.8 | 70 | 11 | 12 | 62 | 6.1 | |
NS200b-25A | 1″(25A) | 25 | 34.2 | 44 | 76 | 12 | 13.5 | 67 | 9.3 | |
NS200b-40A | 11/2″(40A) | 40 | 48.8 | 62 | 110 | 14 | 22 | 267 | 22 | |
NS200b-50A | 2″(50A) | 50 | 61 | 74 | 130 | 15 | 25 | 275 | 38 |
Design pressure : 3.0Mpa
Design temperature : -196℃~75℃
Kind of fluid : LN2, LO2, LAr, LCO2, LNG
Hydrostatic test pressure : 4.5 Mpa
Pneumatic test pressure : 3.3 Mpa
“Bronze Diverter Valve” is designed to divert the safety and rupture disc in cryogenic liquid systems.
This valve is used extensively in safety system for bulk storage tanks, portable liquid cylinders and pipelines for LO2, LN2, LAr and LNG.”
Specifications | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model No. | SIZE | L | H | T | W1 | W2 | Nozzle size | N-1 | N-2 | NN-3 | Φ |
NS400b-15A | 1/2″(15A) | 114 | 106 | 155 | 70 | 30 | " | 1/2″NPT | 1/2″NPT | 3/4″PT | 15mm |
NS400b-25A | 1″(25A) | 136 | 126 | 155 | 80 | 40 | " | 1″NPT | 1″NPT | 1″NPT | 20mm |
NS400b-40A | 11/2″(40A) | 204 | 165 | 183 | 109 | 54 | " | 1 1/2″NPT | 1 1/2″NPT | 1 1/2″NPT | 31mm |
Design pressure : 4.0Mpa
Design temperature : -196℃~75℃
Kind of fluid : LN₂, LO₂, LAr, LCO₂, LNG, LC₂H₄
Hydrostatic test pressure : 6.0 Mpa
Pneumatic test pressure : 4.4 Mpa
Air Supply Pressure : 0.3 ~ 0.8 MPa
“Emergency Shut-off Valve” is exclusively designed to provide positive shut-off in case of emergency in cryogenic liquid systems.
This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂, LAr and LNG.”
Specifications | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model No. | SIZE | ØD | d | d1 | L | L1 | I | W | H | Cv | |
NS150-15A | 1/2″(15A) | 15 | 21.9 | 30 | 62 | 9 | 10 | 80 | 620 | 2.9 | |
NS150-25A | 1″(25A) | 25 | 34.2 | 44 | 76 | 12 | 13.5 | 100 | 660 | 9.3 | |
NS150-40A | 11/2″(40A) | 40 | 48.8 | 62 | 110 | 14 | 22 | 140 | 770 | 22 | |
NS150-50A | 2″(50A) | 50 | 61 | 74 | 130 | 15 | 25 | 140 | 290 | 38 |