로고

글로비스타
로그인 회원가입
  • 제품소개
  • 극저온 및 특수 VALVE
  • 제품소개

    홈페이지를 방문해주셔서 감사합니다.

    극저온 및 특수 VALVE

    극저온 및 특수 VALVE 정보를 안내드립니다.

    NS_100S

    Design pressure : 5.0Mpa

    Design temperature : -196℃~75℃

    Kind of fluid : LN₂, LO₂, LAr, LCO₂, LNG, LC₂H₄

    Hydrostatic test pressure : 7.5 Mpa

    Pneumatic test pressure : 5.5 Mpa


    “SS Cryogenic Long-stem Globe Valve” is designed to provide exactly shut-off of cryogenic liquid systems.

    This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂, LO₂, LAr and LNG. Unique design and manufacturing technology give much better price and more reliability.

    SEMIC
    Specifications
    Model No. SIZE ØD d d1 L L1 I W H Cv
    NS100s-10A-SW 3/8”(10A) 12 17.5 26 56 8 8 80 200 2.0
    NS100s-15A-SW 1/2″(15A) 15 21.9 30 62 9 10 80 245 2.9
    NS100s-20A-SW 3/4″(20A) 20 27.4 36.8 70 11 12 100 270 6.1
    NS100s-25A-SW 1″(25A) 25 34.2 44 76 12 13.5 100 285 9.3
    NS100s-32A-SW 1-1/4”(32A) 32 42.9 52 90 13 16 100 350 14
    NS100s-40A-SW 11/2″(40A) 40 48.8 62 110 14 22 140 430 25
    NS100s-50A-SW 2″(50A) 50 61 74 130 15 25 140 460 38
    NS100s-80A-SW 3″(80A) 80 78 100 210 - 32 200 600 56
    NS100s-100A-SW 4″(100A) 100 98 130 280 - 38 250 700 140
    NS_110S

    Design pressure : 5.0Mpa

    Design temperature : -40℃~75℃

    Kind of fluid : LN₂, LO₂, LAr, LCO₂, LNG, LC₂H₄

    Hydrostatic test pressure : 7.5 Mpa

    Pneumatic test pressure : 5.5 Mpa


    “SS Cryogenic Short-stem Globe Valve” is designed to provide positive shut-off of cryogenic gas systems. This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for O₂, N₂, Ar and NG.

    SEMIC
    Specifications
    Model No. SIZE ØD d d1 L L1 I W H Cv
    NS110s-10A-SW 3/8”(10A) 12 17.5 26 56 8 8 80 160 2.0
    NS110s-15A-SW 1/2″(15A) 15 21.9 30 62 9 10 80 165 2.9
    NS110s-20A-SW 3/4″(20A) 20 27.4 36.8 70 11 12 100 180 6.1
    NS110s-25A-SW 1″(25A) 25 34.2 44 76 12 13.5 100 190 9.3
    NS110s-32A-SW 1-1/4”(32A) 32 42.9 52 90 13 16 100 230 14
    NS110s-40A-SW 11/2″(40A) 40 48.8 62 110 14 22 140 270 25
    NS110s-50A-SW 2″(50A) 50 61 74 130 15 25 140 290 38
    NS110s-80A-SW 3″(80A) 80 78 100 210 - 32 200 350 56
    NS110s-100A-SW 4″(100A) 100 98 130 280 - 38 250 420 140
    NS_110S

    Design pressure : 5.0Mpa

    Design temperature : -196℃~75℃

    Kind of fluid : LN₂, LO₂, LAr, LCO₂, LNG, LC₂H₄

    Hydrostatic test pressure : 7.5 Mpa

    Pneumatic test pressure : 5.5 Mpa


    “SS Cryogenic Lift Check Valve” is designed for use as a check valve which allows fluids to flow in one direction in cryogenic liquid systems. This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂, LAr, and LNG.

    SEMIC
    Specifications
    Model No. SIZE ØD d d1 L L1 I H Cv
    NS200s-15A 1/2″(15A) 15 21.9 30 62 9 10 53 2.9
    NS200s-20A 3/4″(20A) 20 27.4 36.8 70 11 12 62 6.1
    NS200s-25A 1″(25A) 25 34.2 44 76 12 13.5 67 9.3
    NS200s-40A 11/2″(40A) 40 48.8 62 110 14 22 267 22
    NS200s-50A 2″(50A) 50 61 74 130 15 25 275 38
    NS_100B

    Design pressure : 3.0Mpa

    Design temperature : -196℃~75℃

    Kind of fluid : LN2, LO2, LAr, LCO2, LNG, LC₂H₄

    Hydrostatic test pressure : 4.5 Mpa

    Pneumatic test pressure : 3.3 Mpa


    “BC Cryogenic Long-stem Globe Valve” is designed to provide positive shut-off of cryogenic liquid systems. This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂ and LAr. Unique design and manufacturing technology give much better price and more reliability.

    SEMIC
    Specifications
    Model No. SIZE ØD d d1 L L1 I W H Cv
    NS100b-10A-SW 3/8”(10A) 12 17.5 26 56 8 8 80 160 2
    NS100b-15A-SW 1/2″(15A) 15 21.9 30 62 9 10 80 165 2.9
    NS100b-20A-SW 3/4″(20A) 20 27.4 36.8 70 11 12 100 285 6.1
    NS100b-25A-SW 1″(25A) 25 34.2 44 76 12 13.5 100 285 9.3
    NS100b-32A-SW 1-1/4”(32A) 32 42.9 52 90 13 16 100 350 14
    NS100b-40A-SW 11/2″(40A) 40 48.8 62 110 14 22 140 430 25
    NS100b-50A-SW 2″(50A) 50 61 74 130 15 25 140 460 38
    NS_110B

    Design pressure : 3.0Mpa

    Design temperature : -196℃~75℃

    Kind of fluid : N₂, O₂, Ar, CO₂, NG, C₂H₄

    Hydrostatic test pressure : 4.5 Mpa

    Pneumatic test pressure : 3.3 Mpa


    “BC Cryogenic Short-stem Globe Valve” is designed to provide positive shut-off of cryogenic gas systems. This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂, LAr and LNG.”

    SEMIC
    Specifications
    Model No. SIZE ØD d d1 L L1 I W H Cv
    NS110B-10A-SW 3/8”(10A) 12 17.5 26 56 8 8 80 160 2
    NS110B-15A-SW 1/2″(15A) 15 21.9 30 62 9 10 80 165 2.9
    NS110B-20A-SW 3/4″(20A) 20 27.4 36.8 70 11 12 100 180 6.1
    NS110B-25A-SW 1″(25A) 25 34.2 44 76 12 13.5 100 190 9.3
    NS110B-32A-SW 1-1/4”(32A) 32 42.9 52 90 13 16 100 230 14
    NS110B-40A-SW 11/2″(40A) 40 48.8 62 110 14 22 140 270 25
    NS110B-50A-SW 2″(50A) 50 61 74 130 15 25 140 290 38
    NS_200B

    Design pressure : 3.0Mpa

    Design temperature : -196℃~75℃

    Kind of fluid : LN₂, LO₂, LAr, LCO₂, LNG, LC₂H₄

    Hydrostatic test pressure : 4.5 Mpa

    Pneumatic test pressure : 3.3 Mpa


    “BC Cryogenic Lift Check Valve” is designed to provide positive shutoff of cryogenic gas systems. This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂, LAr and LNG.”

    SEMIC
    Specifications
    Model No. SIZE ØD d d1 L L1 I H Cv
    NS200b-15A 1/2″(15A) 15 21.9 30 62 9 10 53 2.9
    NS200b-20A 3/4″(20A) 20 27.4 36.8 70 11 12 62 6.1
    NS200b-25A 1″(25A) 25 34.2 44 76 12 13.5 67 9.3
    NS200b-40A 11/2″(40A) 40 48.8 62 110 14 22 267 22
    NS200b-50A 2″(50A) 50 61 74 130 15 25 275 38
    NS_400B

    Design pressure : 3.0Mpa

    Design temperature : -196℃~75℃

    Kind of fluid : LN2, LO2, LAr, LCO2, LNG

    Hydrostatic test pressure : 4.5 Mpa

    Pneumatic test pressure : 3.3 Mpa


    “Bronze Diverter Valve” is designed to divert the safety and rupture disc in cryogenic liquid systems. This valve is used extensively in safety system for bulk storage tanks, portable liquid cylinders and pipelines for LO2, LN2, LAr and LNG.”

    SEMIC
    Specifications
    Model No. SIZE L H T W1 W2 Nozzle size N-1 N-2 NN-3 Φ
    NS400b-15A 1/2″(15A) 114 106 155 70 30 " 1/2″NPT 1/2″NPT 3/4″PT 15mm
    NS400b-25A 1″(25A) 136 126 155 80 40 " 1″NPT 1″NPT 1″NPT 20mm
    NS400b-40A 11/2″(40A) 204 165 183 109 54 " 1 1/2″NPT 1 1/2″NPT 1 1/2″NPT 31mm
    NS_150

    Design pressure : 4.0Mpa

    Design temperature : -196℃~75℃

    Kind of fluid : LN₂, LO₂, LAr, LCO₂, LNG, LC₂H₄

    Hydrostatic test pressure : 6.0 Mpa

    Pneumatic test pressure : 4.4 Mpa

    Air Supply Pressure : 0.3 ~ 0.8 MPa


    “Emergency Shut-off Valve” is exclusively designed to provide positive shut-off in case of emergency in cryogenic liquid systems. This valve is used extensively in bulk storage tanks, portable liquid cylinders and pipelines for LO₂, LN₂, LAr and LNG.”

    SEMIC
    Specifications
    Model No. SIZE ØD d d1 L L1 I W H Cv
    NS150-15A 1/2″(15A) 15 21.9 30 62 9 10 80 620 2.9
    NS150-25A 1″(25A) 25 34.2 44 76 12 13.5 100 660 9.3
    NS150-40A 11/2″(40A) 40 48.8 62 110 14 22 140 770 22
    NS150-50A 2″(50A) 50 61 74 130 15 25 140 290 38